VTS202/302 - pitless with ramps
|
Important features:
- Maximal capacity: from 40t to 100t
- Weighbridge lenght: 10m,12m,14m,16,18m,21m,24m
- Weighbridge width: 3m or 3.4m (optional)
- Maximum axle load: for VTS202 - up to 14t / VTS302 - up to 20t
- Trucks per day: up to 250
- Accuracy class: class III according EN45501 legal for trade,single range 1 x 3000e...6000e,dual range 2 x 3000e depending on the used loadcells
- Certificates: EC type approval : NMi T2206
Weighbridge construction :
- Production: Mettler Toledo production facility under stringent quality control, ISO9000 certified
- Weighbridge design: #modular orthotropic steel weighbridge with smooth deck plate, Mettler Toledo #steel grade - St 37.2 #robotized continuous weldings #weighbridge design is tested with unique "module tester" simulating 20 years of use passing 250 fully loaded trucks per day across the scale #easy removable ,transportable with 20"/40" container depending on weighbridge length
- Module length: 4m, 5m, 5.8m
- Module thickness: 48cm
- Deckplate thickness: 10mm
- Surface protection: acrylic polyurethane RAL7038
- Installation: above ground with ramps or in shallow/deep pit
- Weighbridge service: from top of the deck through service plates and from side
- Loadcell access: side access or bottom
- Loadcells: High accuracy digital MTX® loadcells,stainless steel case with IP68/IP69K protection or analog 0782 loadcells stainless steel with IP68 protection,approved according OIML R60
- Junction boxes: stainless steel IP67,without trimmers and any adjustments in case of digital loadcells
- Working temperature: from -50ºC to +50ºC
Electronic equipment :
- Weighing terminal: Mettler Toledo IND310,stainless steel with IP69K protection or by customer request with Mettler Toledo IND135, IND780 or IND560
- Features with digital loadcells: predictive maintenance such as scale and loadcell monitoring, calibration management, web server, error logs, E-mail alert, remote diagnostics,replacement of electronic component (loadcell,junction box,indicator) doesn't need recalibration with reference weights
- Possible interfaces: RS232, RS485, TTY, 0/4-20mA, Ethernet, Profibus, Devicenet. ControlNet, Allen Bradley,Modbus, digital I/O
- Lightning protection type Strikeshield,Mettler Toledo tested for 100 000V/10KA - standart delivery
|
IND310
|
IND780
|
IND135
|
IND560
|
Options :
- Side rails
- Antislip plates
- Weighbridge width 3.4m
- Explosion proof design Ex Zone 2,21
- Remote display
|